HomelinessBuilding

The pipe as an element of a ventilation duct

The pipe is a pipe that connects the atmosphere with the sewer riser. In its absence, sewage that falls on the riser creates a certain rarefaction, because of which the liquid from the above siphon (toilet bowl, sink) leaves accompanied by a characteristic sound, and an unpleasant smell of sewage enters the room through this siphon.

A pipe according to these building standards may not be installed during the construction of a sewer system of low-rise construction (two-story buildings). This exception is allowed because of the small volume of a single runoff.

The pipe is an integral part of ventilation in the following cases:

  1. If the building consists of 3 or more residential floors, which are equipped with sanitary facilities;

  2. If the structure has sewage, made of pipes with a diameter of not less than 50 mm;

  3. If the house has any equipment that is able to discharge a large amount of sewage into the sewage system, for example, a pool.

The pipe has a couple of simple installation rules. The first - its diameter should be not less (it is supposed the same) of the diameter of the pipe with which the riser is made, in no case is it possible to narrow it. Second - the end of this pipe should go to a place from which foreign odors can easily escape into the atmosphere. Typically, it is 30-50 cm from the wall. Based on the practice, the pipe is made from the same sewer pipe and is a continuation of the riser pipe. It is introduced into the ventilation duct, which is designed well in advance. In some cases, the outlet of the fan pipe through the wall (horizontal) is allowed with further external decorative trim.

The toilet pipe is installed in a mandatory manner, as often there is an extraneous smell in the building, it would seem, with a normal sewage system and excellent ventilation. The pipe not only sucks in the air, it also ventilates the entire sewage system. Proceeding from this, its installation in a suburban structure allows even with a dried siphon to keep fresh air in the bathroom. If there are four or more risers in the building, all these vertically standing chimneys noticeably spoil the overall design of the building. It was for this purpose that the vacuum valve was created , with the help of which it is possible to install just one fan tube for the entire countryside structure. Its composition includes a sealed rubber seal and a spring. The created rarefaction inside the valve (the result of the falling drains) opens it, which allows the valve to suck in air. When the pressure in the riser is equalized, it closes with the help of a spring, thus preventing unpleasant air from entering the room.

The pipe is a pipe that serves as a connecting element of the sewer riser with the atmosphere, optionally with a ventilation duct. The length and shape of it can be varied. Installation of it is carried out without any complications, as the material and technology of conventional sewage are used. In some cases, a vacuum valve may be installed instead.